Chimney endografting for pararenal aortic pathologies using transfemoral access and the lift technique

2013

Purpose: To present a technique for transfemoral implantation of parallel grafts into the renal arteries in patients with anatomy or morphology that blocks standard antegrade chimney graft delivery. Technique: In a totally percutaneous approach, a 5-F pigtail angiographic catheter is passed into the aorta above the renal arteries via a 0.035-inch hydrophilic guidewire, followed by an 8-F sheath. The target vessel is cannulated with the hydrophilic wire followed by a 5-F reverse curve catheter; the wire is changed for a Rosen wire. The main stent-graft body is delivered and parked at the level of the aortic bifurcation. The Viabahn chimney endograft is advanced ~1 to 2 cm into the target ren…

Settore MED/22 - Chirurgia Vascolareendovascular repair abdominal aorta pararenal aorta aneurysm endovascular aneurysm repair stent-graft chimney graft chimney technique deployment technique self-expanding stent-graft